KROPE, Andrej ;KROPE, Jurij ;TIČAR, Igor . The Reduction of Friction Losses in District-Heating Pipelines. Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 46, n.8, p. 525-531, july 2017. ISSN 0039-2480. Available at: <https://www.sv-jme.eu/sl/article/the-reduction-of-friction-losses-in-district-heating-pipelines/>. Date accessed: 23 dec. 2024. doi:http://dx.doi.org/.
Krope, A., Krope, J., & Tičar, I. (2000). The Reduction of Friction Losses in District-Heating Pipelines. Strojniški vestnik - Journal of Mechanical Engineering, 46(8), 525-531. doi:http://dx.doi.org/
@article{., author = {Andrej Krope and Jurij Krope and Igor Tičar}, title = {The Reduction of Friction Losses in District-Heating Pipelines}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {46}, number = {8}, year = {2000}, keywords = {fliud flow; pressure drops; additives; heating pipelines; }, abstract = {In the paper the impact of cationic surfactant additives on reducing the turbulence intensity in the hot-water pipelines of district heating systems is presented. With small amounts of cationic surfactants in district-heating water the friction losses in pipelines can be reduced significantly. Because of this effect the pressure drops are decreased what leads to reductions in pump energy, pumping costs, costs of gas for heating the supply water, heat losses and to an increase in the heat capacity. New district-heating networks can be designed with smaller pipe diameters and so investment costs can be reduced significantly by applying friction-reducing additives.}, issn = {0039-2480}, pages = {525-531}, doi = {}, url = {https://www.sv-jme.eu/sl/article/the-reduction-of-friction-losses-in-district-heating-pipelines/} }
Krope, A.,Krope, J.,Tičar, I. 2000 July 46. The Reduction of Friction Losses in District-Heating Pipelines. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 46:8
%A Krope, Andrej %A Krope, Jurij %A Tičar, Igor %D 2000 %T The Reduction of Friction Losses in District-Heating Pipelines %B 2000 %9 fliud flow; pressure drops; additives; heating pipelines; %! The Reduction of Friction Losses in District-Heating Pipelines %K fliud flow; pressure drops; additives; heating pipelines; %X In the paper the impact of cationic surfactant additives on reducing the turbulence intensity in the hot-water pipelines of district heating systems is presented. With small amounts of cationic surfactants in district-heating water the friction losses in pipelines can be reduced significantly. Because of this effect the pressure drops are decreased what leads to reductions in pump energy, pumping costs, costs of gas for heating the supply water, heat losses and to an increase in the heat capacity. New district-heating networks can be designed with smaller pipe diameters and so investment costs can be reduced significantly by applying friction-reducing additives. %U https://www.sv-jme.eu/sl/article/the-reduction-of-friction-losses-in-district-heating-pipelines/ %0 Journal Article %R %& 525 %P 7 %J Strojniški vestnik - Journal of Mechanical Engineering %V 46 %N 8 %@ 0039-2480 %8 2017-07-07 %7 2017-07-07
Krope, Andrej, Jurij Krope, & Igor Tičar. "The Reduction of Friction Losses in District-Heating Pipelines." Strojniški vestnik - Journal of Mechanical Engineering [Online], 46.8 (2000): 525-531. Web. 23 Dec. 2024
TY - JOUR AU - Krope, Andrej AU - Krope, Jurij AU - Tičar, Igor PY - 2000 TI - The Reduction of Friction Losses in District-Heating Pipelines JF - Strojniški vestnik - Journal of Mechanical Engineering DO - KW - fliud flow; pressure drops; additives; heating pipelines; N2 - In the paper the impact of cationic surfactant additives on reducing the turbulence intensity in the hot-water pipelines of district heating systems is presented. With small amounts of cationic surfactants in district-heating water the friction losses in pipelines can be reduced significantly. Because of this effect the pressure drops are decreased what leads to reductions in pump energy, pumping costs, costs of gas for heating the supply water, heat losses and to an increase in the heat capacity. New district-heating networks can be designed with smaller pipe diameters and so investment costs can be reduced significantly by applying friction-reducing additives. UR - https://www.sv-jme.eu/sl/article/the-reduction-of-friction-losses-in-district-heating-pipelines/
@article{{}{.}, author = {Krope, A., Krope, J., Tičar, I.}, title = {The Reduction of Friction Losses in District-Heating Pipelines}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {46}, number = {8}, year = {2000}, doi = {}, url = {https://www.sv-jme.eu/sl/article/the-reduction-of-friction-losses-in-district-heating-pipelines/} }
TY - JOUR AU - Krope, Andrej AU - Krope, Jurij AU - Tičar, Igor PY - 2017/07/07 TI - The Reduction of Friction Losses in District-Heating Pipelines JF - Strojniški vestnik - Journal of Mechanical Engineering; Vol 46, No 8 (2000): Strojniški vestnik - Journal of Mechanical Engineering DO - KW - fliud flow, pressure drops, additives, heating pipelines, N2 - In the paper the impact of cationic surfactant additives on reducing the turbulence intensity in the hot-water pipelines of district heating systems is presented. With small amounts of cationic surfactants in district-heating water the friction losses in pipelines can be reduced significantly. Because of this effect the pressure drops are decreased what leads to reductions in pump energy, pumping costs, costs of gas for heating the supply water, heat losses and to an increase in the heat capacity. New district-heating networks can be designed with smaller pipe diameters and so investment costs can be reduced significantly by applying friction-reducing additives. UR - https://www.sv-jme.eu/sl/article/the-reduction-of-friction-losses-in-district-heating-pipelines/
Krope, Andrej, Krope, Jurij, AND Tičar, Igor. "The Reduction of Friction Losses in District-Heating Pipelines" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 46 Number 8 (07 July 2017)
Strojniški vestnik - Journal of Mechanical Engineering 46(2000)8, 525-531
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.
In the paper the impact of cationic surfactant additives on reducing the turbulence intensity in the hot-water pipelines of district heating systems is presented. With small amounts of cationic surfactants in district-heating water the friction losses in pipelines can be reduced significantly. Because of this effect the pressure drops are decreased what leads to reductions in pump energy, pumping costs, costs of gas for heating the supply water, heat losses and to an increase in the heat capacity. New district-heating networks can be designed with smaller pipe diameters and so investment costs can be reduced significantly by applying friction-reducing additives.