Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool

1903 Ogledov
926 Prenosov
Izvoz citacije: ABNT
BOLTEŽAR, Marko .
Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 50, n.7-8, p. 376-385, july 2017. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/sl/article/determining-the-sensitivity-of-an-ultrasonic-heat-meter-using-the-ansys-analysis-tool/>. Date accessed: 19 nov. 2024. 
doi:http://dx.doi.org/.
Boltežar, M.
(2004).
Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool.
Strojniški vestnik - Journal of Mechanical Engineering, 50(7-8), 376-385.
doi:http://dx.doi.org/
@article{.,
	author = {Marko  Boltežar},
	title = {Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {50},
	number = {7-8},
	year = {2004},
	keywords = {utrasonic heat meters; sensitivity; software packages; ANSYS; },
	abstract = {In this paper an investigation of the sensitivity of an ultrasonic heat meter is presented. The goal of the investigation was to determine the shape of the flow measuring cell that gives the maximum sensitivity. The simulation involved the program package ANSYS, which is based on the finite-element method (FEM). The FEM results were experimentally verified. The simulations turned out to be very close to the actual flow conditions within the flow unit of the heat meter. The experimental results agree well with theory. The final result of the FEM analysis and the experimental measurements is a prototype of the measuring cell that ensures the required sensitivity of the heat meter.},
	issn = {0039-2480},	pages = {376-385},	doi = {},
	url = {https://www.sv-jme.eu/sl/article/determining-the-sensitivity-of-an-ultrasonic-heat-meter-using-the-ansys-analysis-tool/}
}
Boltežar, M.
2004 July 50. Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 50:7-8
%A Boltežar, Marko 
%D 2004
%T Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool
%B 2004
%9 utrasonic heat meters; sensitivity; software packages; ANSYS; 
%! Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool
%K utrasonic heat meters; sensitivity; software packages; ANSYS; 
%X In this paper an investigation of the sensitivity of an ultrasonic heat meter is presented. The goal of the investigation was to determine the shape of the flow measuring cell that gives the maximum sensitivity. The simulation involved the program package ANSYS, which is based on the finite-element method (FEM). The FEM results were experimentally verified. The simulations turned out to be very close to the actual flow conditions within the flow unit of the heat meter. The experimental results agree well with theory. The final result of the FEM analysis and the experimental measurements is a prototype of the measuring cell that ensures the required sensitivity of the heat meter.
%U https://www.sv-jme.eu/sl/article/determining-the-sensitivity-of-an-ultrasonic-heat-meter-using-the-ansys-analysis-tool/
%0 Journal Article
%R 
%& 376
%P 10
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 50
%N 7-8
%@ 0039-2480
%8 2017-07-07
%7 2017-07-07
Boltežar, Marko.
"Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool." Strojniški vestnik - Journal of Mechanical Engineering [Online], 50.7-8 (2004): 376-385. Web.  19 Nov. 2024
TY  - JOUR
AU  - Boltežar, Marko 
PY  - 2004
TI  - Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - utrasonic heat meters; sensitivity; software packages; ANSYS; 
N2  - In this paper an investigation of the sensitivity of an ultrasonic heat meter is presented. The goal of the investigation was to determine the shape of the flow measuring cell that gives the maximum sensitivity. The simulation involved the program package ANSYS, which is based on the finite-element method (FEM). The FEM results were experimentally verified. The simulations turned out to be very close to the actual flow conditions within the flow unit of the heat meter. The experimental results agree well with theory. The final result of the FEM analysis and the experimental measurements is a prototype of the measuring cell that ensures the required sensitivity of the heat meter.
UR  - https://www.sv-jme.eu/sl/article/determining-the-sensitivity-of-an-ultrasonic-heat-meter-using-the-ansys-analysis-tool/
@article{{}{.},
	author = {Boltežar, M.},
	title = {Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {50},
	number = {7-8},
	year = {2004},
	doi = {},
	url = {https://www.sv-jme.eu/sl/article/determining-the-sensitivity-of-an-ultrasonic-heat-meter-using-the-ansys-analysis-tool/}
}
TY  - JOUR
AU  - Boltežar, Marko 
PY  - 2017/07/07
TI  - Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 50, No 7-8 (2004): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - utrasonic heat meters, sensitivity, software packages, ANSYS, 
N2  - In this paper an investigation of the sensitivity of an ultrasonic heat meter is presented. The goal of the investigation was to determine the shape of the flow measuring cell that gives the maximum sensitivity. The simulation involved the program package ANSYS, which is based on the finite-element method (FEM). The FEM results were experimentally verified. The simulations turned out to be very close to the actual flow conditions within the flow unit of the heat meter. The experimental results agree well with theory. The final result of the FEM analysis and the experimental measurements is a prototype of the measuring cell that ensures the required sensitivity of the heat meter.
UR  - https://www.sv-jme.eu/sl/article/determining-the-sensitivity-of-an-ultrasonic-heat-meter-using-the-ansys-analysis-tool/
Boltežar, Marko"Determining the Sensitivity of an Ultrasonic Heat Meter Using the ANSYS Analysis Tool" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 50 Number 7-8 (07 July 2017)

Avtorji

Inštitucije

  • ISKRA EMECO d. d., Kranj, Slovenia

Informacije o papirju

Strojniški vestnik - Journal of Mechanical Engineering 50(2004)7-8, 376-385
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

In this paper an investigation of the sensitivity of an ultrasonic heat meter is presented. The goal of the investigation was to determine the shape of the flow measuring cell that gives the maximum sensitivity. The simulation involved the program package ANSYS, which is based on the finite-element method (FEM). The FEM results were experimentally verified. The simulations turned out to be very close to the actual flow conditions within the flow unit of the heat meter. The experimental results agree well with theory. The final result of the FEM analysis and the experimental measurements is a prototype of the measuring cell that ensures the required sensitivity of the heat meter.

utrasonic heat meters; sensitivity; software packages; ANSYS;