KOVAČ, Igor ;KLEIN, Andreas . Apparatus and a Procedure to Calibrate Coordinate Measuring Arms. Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 48, n.1, p. 17-32, july 2017. ISSN 0039-2480. Available at: <https://www.sv-jme.eu/sl/article/apparatus-and-a-procedure-to-calibrate-coordinate-measuring-arms/>. Date accessed: 20 dec. 2024. doi:http://dx.doi.org/.
Kovač, I., & Klein, A. (2002). Apparatus and a Procedure to Calibrate Coordinate Measuring Arms. Strojniški vestnik - Journal of Mechanical Engineering, 48(1), 17-32. doi:http://dx.doi.org/
@article{., author = {Igor Kovač and Andreas Klein}, title = {Apparatus and a Procedure to Calibrate Coordinate Measuring Arms}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {48}, number = {1}, year = {2002}, keywords = {coordinate measuring devices; portable devices; straightness measurements; calibrations; }, abstract = {A technique for increasing the absolute accuracy of portable, coordinate measuring arms with exclusively rotational axes was developed. This new technique is based on calibration measurements along a straight line that is adjusted in various spatial directions. For this reason a special, new, high-precision calibration apparatus was developed to collect a representative quantity of accurate data needed for the successful calibration. Parameter identification was carried out using the RoboCal calibration software. The calibration procedure using the high-precision calibration apparatus can improve the pose accuracy of the coordinate measuring arm drastically. This was also confirmed by our experiments.}, issn = {0039-2480}, pages = {17-32}, doi = {}, url = {https://www.sv-jme.eu/sl/article/apparatus-and-a-procedure-to-calibrate-coordinate-measuring-arms/} }
Kovač, I.,Klein, A. 2002 July 48. Apparatus and a Procedure to Calibrate Coordinate Measuring Arms. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 48:1
%A Kovač, Igor %A Klein, Andreas %D 2002 %T Apparatus and a Procedure to Calibrate Coordinate Measuring Arms %B 2002 %9 coordinate measuring devices; portable devices; straightness measurements; calibrations; %! Apparatus and a Procedure to Calibrate Coordinate Measuring Arms %K coordinate measuring devices; portable devices; straightness measurements; calibrations; %X A technique for increasing the absolute accuracy of portable, coordinate measuring arms with exclusively rotational axes was developed. This new technique is based on calibration measurements along a straight line that is adjusted in various spatial directions. For this reason a special, new, high-precision calibration apparatus was developed to collect a representative quantity of accurate data needed for the successful calibration. Parameter identification was carried out using the RoboCal calibration software. The calibration procedure using the high-precision calibration apparatus can improve the pose accuracy of the coordinate measuring arm drastically. This was also confirmed by our experiments. %U https://www.sv-jme.eu/sl/article/apparatus-and-a-procedure-to-calibrate-coordinate-measuring-arms/ %0 Journal Article %R %& 17 %P 16 %J Strojniški vestnik - Journal of Mechanical Engineering %V 48 %N 1 %@ 0039-2480 %8 2017-07-07 %7 2017-07-07
Kovač, Igor, & Andreas Klein. "Apparatus and a Procedure to Calibrate Coordinate Measuring Arms." Strojniški vestnik - Journal of Mechanical Engineering [Online], 48.1 (2002): 17-32. Web. 20 Dec. 2024
TY - JOUR AU - Kovač, Igor AU - Klein, Andreas PY - 2002 TI - Apparatus and a Procedure to Calibrate Coordinate Measuring Arms JF - Strojniški vestnik - Journal of Mechanical Engineering DO - KW - coordinate measuring devices; portable devices; straightness measurements; calibrations; N2 - A technique for increasing the absolute accuracy of portable, coordinate measuring arms with exclusively rotational axes was developed. This new technique is based on calibration measurements along a straight line that is adjusted in various spatial directions. For this reason a special, new, high-precision calibration apparatus was developed to collect a representative quantity of accurate data needed for the successful calibration. Parameter identification was carried out using the RoboCal calibration software. The calibration procedure using the high-precision calibration apparatus can improve the pose accuracy of the coordinate measuring arm drastically. This was also confirmed by our experiments. UR - https://www.sv-jme.eu/sl/article/apparatus-and-a-procedure-to-calibrate-coordinate-measuring-arms/
@article{{}{.}, author = {Kovač, I., Klein, A.}, title = {Apparatus and a Procedure to Calibrate Coordinate Measuring Arms}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {48}, number = {1}, year = {2002}, doi = {}, url = {https://www.sv-jme.eu/sl/article/apparatus-and-a-procedure-to-calibrate-coordinate-measuring-arms/} }
TY - JOUR AU - Kovač, Igor AU - Klein, Andreas PY - 2017/07/07 TI - Apparatus and a Procedure to Calibrate Coordinate Measuring Arms JF - Strojniški vestnik - Journal of Mechanical Engineering; Vol 48, No 1 (2002): Strojniški vestnik - Journal of Mechanical Engineering DO - KW - coordinate measuring devices, portable devices, straightness measurements, calibrations, N2 - A technique for increasing the absolute accuracy of portable, coordinate measuring arms with exclusively rotational axes was developed. This new technique is based on calibration measurements along a straight line that is adjusted in various spatial directions. For this reason a special, new, high-precision calibration apparatus was developed to collect a representative quantity of accurate data needed for the successful calibration. Parameter identification was carried out using the RoboCal calibration software. The calibration procedure using the high-precision calibration apparatus can improve the pose accuracy of the coordinate measuring arm drastically. This was also confirmed by our experiments. UR - https://www.sv-jme.eu/sl/article/apparatus-and-a-procedure-to-calibrate-coordinate-measuring-arms/
Kovač, Igor, AND Klein, Andreas. "Apparatus and a Procedure to Calibrate Coordinate Measuring Arms" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 48 Number 1 (07 July 2017)
Strojniški vestnik - Journal of Mechanical Engineering 48(2002)1, 17-32
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.
A technique for increasing the absolute accuracy of portable, coordinate measuring arms with exclusively rotational axes was developed. This new technique is based on calibration measurements along a straight line that is adjusted in various spatial directions. For this reason a special, new, high-precision calibration apparatus was developed to collect a representative quantity of accurate data needed for the successful calibration. Parameter identification was carried out using the RoboCal calibration software. The calibration procedure using the high-precision calibration apparatus can improve the pose accuracy of the coordinate measuring arm drastically. This was also confirmed by our experiments.