Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head

2414 Views
2425 Downloads
Export citation: ABNT
NOVAK, Boštjan ;BABNIK, Aleš ;MOŽINA, Janez ;JEZERŠEK, Matija .
Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 60, n.11, p. 685-693, june 2018. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/article/three-dimensional-foot-scanning-system-with-a-rotational-laser-based-measuring-head/>. Date accessed: 20 dec. 2024. 
doi:http://dx.doi.org/10.5545/sv-jme.2014.1950.
Novak, B., Babnik, A., Možina, J., & Jezeršek, M.
(2014).
Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head.
Strojniški vestnik - Journal of Mechanical Engineering, 60(11), 685-693.
doi:http://dx.doi.org/10.5545/sv-jme.2014.1950
@article{sv-jmesv-jme.2014.1950,
	author = {Boštjan  Novak and Aleš  Babnik and Janez  Možina and Matija  Jezeršek},
	title = {Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {60},
	number = {11},
	year = {2014},
	keywords = {3D foot measurement; laser-multiple-line-triangulation; foot dimensions; footwear fit},
	abstract = {Three-dimensional (3D) measurements of the feet is crucial for the correct design and selection of shoes. Badly-fitting shoes are one of the major causes of pain, foot related diseases and injuries of the feet. This article presents a new system for 3D foot-shape measurements which is based on the laser-multiple-line-triangulation principle. The main part of a system is the measuring head comprising a three laser lines projection unit and two cameras, which rotate around the centre of the platform that the customer stands on, and measures both feet simultaneously. The developed software analyzes the different foot dimensions and suggests the most suitable model and size of a shoe from a database to the customer. Three experiments have been presented to demonstrate the measuring precision of the system: the in-vitro measurement of plastic feet, in-vivo within an hour and in-vivo within one week. The results show that the standard deviation for all feet dimensions is better than 0.6mm in in-vitro case.},
	issn = {0039-2480},	pages = {685-693},	doi = {10.5545/sv-jme.2014.1950},
	url = {https://www.sv-jme.eu/article/three-dimensional-foot-scanning-system-with-a-rotational-laser-based-measuring-head/}
}
Novak, B.,Babnik, A.,Možina, J.,Jezeršek, M.
2014 June 60. Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 60:11
%A Novak, Boštjan 
%A Babnik, Aleš 
%A Možina, Janez 
%A Jezeršek, Matija 
%D 2014
%T Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head
%B 2014
%9 3D foot measurement; laser-multiple-line-triangulation; foot dimensions; footwear fit
%! Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head
%K 3D foot measurement; laser-multiple-line-triangulation; foot dimensions; footwear fit
%X Three-dimensional (3D) measurements of the feet is crucial for the correct design and selection of shoes. Badly-fitting shoes are one of the major causes of pain, foot related diseases and injuries of the feet. This article presents a new system for 3D foot-shape measurements which is based on the laser-multiple-line-triangulation principle. The main part of a system is the measuring head comprising a three laser lines projection unit and two cameras, which rotate around the centre of the platform that the customer stands on, and measures both feet simultaneously. The developed software analyzes the different foot dimensions and suggests the most suitable model and size of a shoe from a database to the customer. Three experiments have been presented to demonstrate the measuring precision of the system: the in-vitro measurement of plastic feet, in-vivo within an hour and in-vivo within one week. The results show that the standard deviation for all feet dimensions is better than 0.6mm in in-vitro case.
%U https://www.sv-jme.eu/article/three-dimensional-foot-scanning-system-with-a-rotational-laser-based-measuring-head/
%0 Journal Article
%R 10.5545/sv-jme.2014.1950
%& 685
%P 9
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 60
%N 11
%@ 0039-2480
%8 2018-06-28
%7 2018-06-28
Novak, Boštjan, Aleš  Babnik, Janez  Možina, & Matija  Jezeršek.
"Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head." Strojniški vestnik - Journal of Mechanical Engineering [Online], 60.11 (2014): 685-693. Web.  20 Dec. 2024
TY  - JOUR
AU  - Novak, Boštjan 
AU  - Babnik, Aleš 
AU  - Možina, Janez 
AU  - Jezeršek, Matija 
PY  - 2014
TI  - Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 10.5545/sv-jme.2014.1950
KW  - 3D foot measurement; laser-multiple-line-triangulation; foot dimensions; footwear fit
N2  - Three-dimensional (3D) measurements of the feet is crucial for the correct design and selection of shoes. Badly-fitting shoes are one of the major causes of pain, foot related diseases and injuries of the feet. This article presents a new system for 3D foot-shape measurements which is based on the laser-multiple-line-triangulation principle. The main part of a system is the measuring head comprising a three laser lines projection unit and two cameras, which rotate around the centre of the platform that the customer stands on, and measures both feet simultaneously. The developed software analyzes the different foot dimensions and suggests the most suitable model and size of a shoe from a database to the customer. Three experiments have been presented to demonstrate the measuring precision of the system: the in-vitro measurement of plastic feet, in-vivo within an hour and in-vivo within one week. The results show that the standard deviation for all feet dimensions is better than 0.6mm in in-vitro case.
UR  - https://www.sv-jme.eu/article/three-dimensional-foot-scanning-system-with-a-rotational-laser-based-measuring-head/
@article{{sv-jme}{sv-jme.2014.1950},
	author = {Novak, B., Babnik, A., Možina, J., Jezeršek, M.},
	title = {Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {60},
	number = {11},
	year = {2014},
	doi = {10.5545/sv-jme.2014.1950},
	url = {https://www.sv-jme.eu/article/three-dimensional-foot-scanning-system-with-a-rotational-laser-based-measuring-head/}
}
TY  - JOUR
AU  - Novak, Boštjan 
AU  - Babnik, Aleš 
AU  - Možina, Janez 
AU  - Jezeršek, Matija 
PY  - 2018/06/28
TI  - Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 60, No 11 (2014): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 10.5545/sv-jme.2014.1950
KW  - 3D foot measurement, laser-multiple-line-triangulation, foot dimensions, footwear fit
N2  - Three-dimensional (3D) measurements of the feet is crucial for the correct design and selection of shoes. Badly-fitting shoes are one of the major causes of pain, foot related diseases and injuries of the feet. This article presents a new system for 3D foot-shape measurements which is based on the laser-multiple-line-triangulation principle. The main part of a system is the measuring head comprising a three laser lines projection unit and two cameras, which rotate around the centre of the platform that the customer stands on, and measures both feet simultaneously. The developed software analyzes the different foot dimensions and suggests the most suitable model and size of a shoe from a database to the customer. Three experiments have been presented to demonstrate the measuring precision of the system: the in-vitro measurement of plastic feet, in-vivo within an hour and in-vivo within one week. The results show that the standard deviation for all feet dimensions is better than 0.6mm in in-vitro case.
UR  - https://www.sv-jme.eu/article/three-dimensional-foot-scanning-system-with-a-rotational-laser-based-measuring-head/
Novak, Boštjan, Babnik, Aleš, Možina, Janez, AND Jezeršek, Matija.
"Three-Dimensional Foot Scanning System with a Rotational Laser-Based Measuring Head" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 60 Number 11 (28 June 2018)

Authors

Affiliations

  • Alpina d.o.o., Slovenia 1
  • University of Ljubljana, Faculty of Mechanical Engineering, Slovenia 2

Paper's information

Strojniški vestnik - Journal of Mechanical Engineering 60(2014)11, 685-693
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

https://doi.org/10.5545/sv-jme.2014.1950

Three-dimensional (3D) measurements of the feet is crucial for the correct design and selection of shoes. Badly-fitting shoes are one of the major causes of pain, foot related diseases and injuries of the feet. This article presents a new system for 3D foot-shape measurements which is based on the laser-multiple-line-triangulation principle. The main part of a system is the measuring head comprising a three laser lines projection unit and two cameras, which rotate around the centre of the platform that the customer stands on, and measures both feet simultaneously. The developed software analyzes the different foot dimensions and suggests the most suitable model and size of a shoe from a database to the customer. Three experiments have been presented to demonstrate the measuring precision of the system: the in-vitro measurement of plastic feet, in-vivo within an hour and in-vivo within one week. The results show that the standard deviation for all feet dimensions is better than 0.6mm in in-vitro case.

3D foot measurement; laser-multiple-line-triangulation; foot dimensions; footwear fit