REMEC, Janko ;ARHAR, Andrej . The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers. Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 46, n.8, p. 564-572, july 2017. ISSN 0039-2480. Available at: <https://www.sv-jme.eu/article/the-possibilities-of-reducing-the-temperature-of-the-heat-source-for-absorption-chillers/>. Date accessed: 21 dec. 2024. doi:http://dx.doi.org/.
Remec, J., & Arhar, A. (2000). The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers. Strojniški vestnik - Journal of Mechanical Engineering, 46(8), 564-572. doi:http://dx.doi.org/
@article{., author = {Janko Remec and Andrej Arhar}, title = {The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {46}, number = {8}, year = {2000}, keywords = {generators; falling-film; lithium bromide; heat transfer; }, abstract = {The increasing importance of the simultaneous production of electricity, heat and cold results in increasingly rigorous demands on absorption chillers. These devices should be smaller, having a low cooling capacity and they have to be able to use low-temperature heating water at 90°C or below. As a result, changes in generator construction are needed. Falling-film generators allow the use of hot water with lower temperatures. This type of generator avoids the need for high hydrostatic pressure, requires lower superheating and diminishes solution mixing. Consequently, we can use hot water at a temperature 7°C lower and reach the same cooling capacity.}, issn = {0039-2480}, pages = {564-572}, doi = {}, url = {https://www.sv-jme.eu/article/the-possibilities-of-reducing-the-temperature-of-the-heat-source-for-absorption-chillers/} }
Remec, J.,Arhar, A. 2000 July 46. The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 46:8
%A Remec, Janko %A Arhar, Andrej %D 2000 %T The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers %B 2000 %9 generators; falling-film; lithium bromide; heat transfer; %! The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers %K generators; falling-film; lithium bromide; heat transfer; %X The increasing importance of the simultaneous production of electricity, heat and cold results in increasingly rigorous demands on absorption chillers. These devices should be smaller, having a low cooling capacity and they have to be able to use low-temperature heating water at 90°C or below. As a result, changes in generator construction are needed. Falling-film generators allow the use of hot water with lower temperatures. This type of generator avoids the need for high hydrostatic pressure, requires lower superheating and diminishes solution mixing. Consequently, we can use hot water at a temperature 7°C lower and reach the same cooling capacity. %U https://www.sv-jme.eu/article/the-possibilities-of-reducing-the-temperature-of-the-heat-source-for-absorption-chillers/ %0 Journal Article %R %& 564 %P 9 %J Strojniški vestnik - Journal of Mechanical Engineering %V 46 %N 8 %@ 0039-2480 %8 2017-07-07 %7 2017-07-07
Remec, Janko, & Andrej Arhar. "The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers." Strojniški vestnik - Journal of Mechanical Engineering [Online], 46.8 (2000): 564-572. Web. 21 Dec. 2024
TY - JOUR AU - Remec, Janko AU - Arhar, Andrej PY - 2000 TI - The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers JF - Strojniški vestnik - Journal of Mechanical Engineering DO - KW - generators; falling-film; lithium bromide; heat transfer; N2 - The increasing importance of the simultaneous production of electricity, heat and cold results in increasingly rigorous demands on absorption chillers. These devices should be smaller, having a low cooling capacity and they have to be able to use low-temperature heating water at 90°C or below. As a result, changes in generator construction are needed. Falling-film generators allow the use of hot water with lower temperatures. This type of generator avoids the need for high hydrostatic pressure, requires lower superheating and diminishes solution mixing. Consequently, we can use hot water at a temperature 7°C lower and reach the same cooling capacity. UR - https://www.sv-jme.eu/article/the-possibilities-of-reducing-the-temperature-of-the-heat-source-for-absorption-chillers/
@article{{}{.}, author = {Remec, J., Arhar, A.}, title = {The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {46}, number = {8}, year = {2000}, doi = {}, url = {https://www.sv-jme.eu/article/the-possibilities-of-reducing-the-temperature-of-the-heat-source-for-absorption-chillers/} }
TY - JOUR AU - Remec, Janko AU - Arhar, Andrej PY - 2017/07/07 TI - The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers JF - Strojniški vestnik - Journal of Mechanical Engineering; Vol 46, No 8 (2000): Strojniški vestnik - Journal of Mechanical Engineering DO - KW - generators, falling-film, lithium bromide, heat transfer, N2 - The increasing importance of the simultaneous production of electricity, heat and cold results in increasingly rigorous demands on absorption chillers. These devices should be smaller, having a low cooling capacity and they have to be able to use low-temperature heating water at 90°C or below. As a result, changes in generator construction are needed. Falling-film generators allow the use of hot water with lower temperatures. This type of generator avoids the need for high hydrostatic pressure, requires lower superheating and diminishes solution mixing. Consequently, we can use hot water at a temperature 7°C lower and reach the same cooling capacity. UR - https://www.sv-jme.eu/article/the-possibilities-of-reducing-the-temperature-of-the-heat-source-for-absorption-chillers/
Remec, Janko, AND Arhar, Andrej. "The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 46 Number 8 (07 July 2017)
Strojniški vestnik - Journal of Mechanical Engineering 46(2000)8, 564-572
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.
The increasing importance of the simultaneous production of electricity, heat and cold results in increasingly rigorous demands on absorption chillers. These devices should be smaller, having a low cooling capacity and they have to be able to use low-temperature heating water at 90°C or below. As a result, changes in generator construction are needed. Falling-film generators allow the use of hot water with lower temperatures. This type of generator avoids the need for high hydrostatic pressure, requires lower superheating and diminishes solution mixing. Consequently, we can use hot water at a temperature 7°C lower and reach the same cooling capacity.