MUHIČ, Simon ;MAZEJ, Mitja ;BUTALA, Vincenc . Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness. Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 54, n.9, p. 579-587, august 2017. ISSN 0039-2480. Available at: <https://www.sv-jme.eu/article/relative-decrease-of-tracer-gas-concentration-as-a-measure-of-the-ventilation-effectiveness/>. Date accessed: 20 dec. 2024. doi:http://dx.doi.org/.
Muhič, S., Mazej, M., & Butala, V. (2008). Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness. Strojniški vestnik - Journal of Mechanical Engineering, 54(9), 579-587. doi:http://dx.doi.org/
@article{., author = {Simon Muhič and Mitja Mazej and Vincenc Butala}, title = {Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {54}, number = {9}, year = {2008}, keywords = {air distribution; air conditioning; ventilation; efficiency; }, abstract = {An analysis of the ventilation effectiveness measured on a prototype system for local air-conditioning named PERMICS (Personal Microclimate System) was made based on simultaneous measurements of velocity field and of tracer gas concentration using the decay method. A new parameter based on a relative decrease of tracer gas concentration in the first minute of system operation dC(1) was introduced. The newly defined parameter has been verified by simulation results from commercial computational fluid dynamics (CFD) software. The usefulness of the parameter is the possibility to make quick measurements of the local efficiency of personalized ventilation systems.}, issn = {0039-2480}, pages = {579-587}, doi = {}, url = {https://www.sv-jme.eu/article/relative-decrease-of-tracer-gas-concentration-as-a-measure-of-the-ventilation-effectiveness/} }
Muhič, S.,Mazej, M.,Butala, V. 2008 August 54. Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 54:9
%A Muhič, Simon %A Mazej, Mitja %A Butala, Vincenc %D 2008 %T Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness %B 2008 %9 air distribution; air conditioning; ventilation; efficiency; %! Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness %K air distribution; air conditioning; ventilation; efficiency; %X An analysis of the ventilation effectiveness measured on a prototype system for local air-conditioning named PERMICS (Personal Microclimate System) was made based on simultaneous measurements of velocity field and of tracer gas concentration using the decay method. A new parameter based on a relative decrease of tracer gas concentration in the first minute of system operation dC(1) was introduced. The newly defined parameter has been verified by simulation results from commercial computational fluid dynamics (CFD) software. The usefulness of the parameter is the possibility to make quick measurements of the local efficiency of personalized ventilation systems. %U https://www.sv-jme.eu/article/relative-decrease-of-tracer-gas-concentration-as-a-measure-of-the-ventilation-effectiveness/ %0 Journal Article %R %& 579 %P 9 %J Strojniški vestnik - Journal of Mechanical Engineering %V 54 %N 9 %@ 0039-2480 %8 2017-08-21 %7 2017-08-21
Muhič, Simon, Mitja Mazej, & Vincenc Butala. "Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness." Strojniški vestnik - Journal of Mechanical Engineering [Online], 54.9 (2008): 579-587. Web. 20 Dec. 2024
TY - JOUR AU - Muhič, Simon AU - Mazej, Mitja AU - Butala, Vincenc PY - 2008 TI - Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness JF - Strojniški vestnik - Journal of Mechanical Engineering DO - KW - air distribution; air conditioning; ventilation; efficiency; N2 - An analysis of the ventilation effectiveness measured on a prototype system for local air-conditioning named PERMICS (Personal Microclimate System) was made based on simultaneous measurements of velocity field and of tracer gas concentration using the decay method. A new parameter based on a relative decrease of tracer gas concentration in the first minute of system operation dC(1) was introduced. The newly defined parameter has been verified by simulation results from commercial computational fluid dynamics (CFD) software. The usefulness of the parameter is the possibility to make quick measurements of the local efficiency of personalized ventilation systems. UR - https://www.sv-jme.eu/article/relative-decrease-of-tracer-gas-concentration-as-a-measure-of-the-ventilation-effectiveness/
@article{{}{.}, author = {Muhič, S., Mazej, M., Butala, V.}, title = {Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness}, journal = {Strojniški vestnik - Journal of Mechanical Engineering}, volume = {54}, number = {9}, year = {2008}, doi = {}, url = {https://www.sv-jme.eu/article/relative-decrease-of-tracer-gas-concentration-as-a-measure-of-the-ventilation-effectiveness/} }
TY - JOUR AU - Muhič, Simon AU - Mazej, Mitja AU - Butala, Vincenc PY - 2017/08/21 TI - Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness JF - Strojniški vestnik - Journal of Mechanical Engineering; Vol 54, No 9 (2008): Strojniški vestnik - Journal of Mechanical Engineering DO - KW - air distribution, air conditioning, ventilation, efficiency, N2 - An analysis of the ventilation effectiveness measured on a prototype system for local air-conditioning named PERMICS (Personal Microclimate System) was made based on simultaneous measurements of velocity field and of tracer gas concentration using the decay method. A new parameter based on a relative decrease of tracer gas concentration in the first minute of system operation dC(1) was introduced. The newly defined parameter has been verified by simulation results from commercial computational fluid dynamics (CFD) software. The usefulness of the parameter is the possibility to make quick measurements of the local efficiency of personalized ventilation systems. UR - https://www.sv-jme.eu/article/relative-decrease-of-tracer-gas-concentration-as-a-measure-of-the-ventilation-effectiveness/
Muhič, Simon, Mazej, Mitja, AND Butala, Vincenc. "Relative decrease of tracer gas concentration as a measure of the ventilation effectiveness" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 54 Number 9 (21 August 2017)
Strojniški vestnik - Journal of Mechanical Engineering 54(2008)9, 579-587
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.
An analysis of the ventilation effectiveness measured on a prototype system for local air-conditioning named PERMICS (Personal Microclimate System) was made based on simultaneous measurements of velocity field and of tracer gas concentration using the decay method. A new parameter based on a relative decrease of tracer gas concentration in the first minute of system operation dC(1) was introduced. The newly defined parameter has been verified by simulation results from commercial computational fluid dynamics (CFD) software. The usefulness of the parameter is the possibility to make quick measurements of the local efficiency of personalized ventilation systems.