Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators

2129 Views
966 Downloads
Export citation: ABNT
CIZELJ, Leon ;ANDROJNA, Ferdo .
Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 46, n.3, p. 152-161, july 2017. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/article/aging-of-tubes-in-the-krsko-nuclear-power-plants-steam-generators/>. Date accessed: 20 dec. 2024. 
doi:http://dx.doi.org/.
Cizelj, L., & Androjna, F.
(2000).
Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators.
Strojniški vestnik - Journal of Mechanical Engineering, 46(3), 152-161.
doi:http://dx.doi.org/
@article{.,
	author = {Leon  Cizelj and Ferdo  Androjna},
	title = {Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {46},
	number = {3},
	year = {2000},
	keywords = {safety, aging; Inconel 600; steam generators; },
	abstract = {The paper reviews the domestic efforts devoted to the safe and reliable operation of the Krško nuclear power plant (NPP) at full power, close to the design limit of the steam generators (18% of plugged tubes) for a full decade. This includes an overview of the recent status and history of the degradation processes, discussion of repair criteria, defining the acceptable size of defects and selected results from safety analyses supporting the operation of degraded steam generator (SG) tubes. It is concluded that Krško NPP operated with degraded, but safe, steam generators.},
	issn = {0039-2480},	pages = {152-161},	doi = {},
	url = {https://www.sv-jme.eu/article/aging-of-tubes-in-the-krsko-nuclear-power-plants-steam-generators/}
}
Cizelj, L.,Androjna, F.
2000 July 46. Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 46:3
%A Cizelj, Leon 
%A Androjna, Ferdo 
%D 2000
%T Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators
%B 2000
%9 safety, aging; Inconel 600; steam generators; 
%! Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators
%K safety, aging; Inconel 600; steam generators; 
%X The paper reviews the domestic efforts devoted to the safe and reliable operation of the Krško nuclear power plant (NPP) at full power, close to the design limit of the steam generators (18% of plugged tubes) for a full decade. This includes an overview of the recent status and history of the degradation processes, discussion of repair criteria, defining the acceptable size of defects and selected results from safety analyses supporting the operation of degraded steam generator (SG) tubes. It is concluded that Krško NPP operated with degraded, but safe, steam generators.
%U https://www.sv-jme.eu/article/aging-of-tubes-in-the-krsko-nuclear-power-plants-steam-generators/
%0 Journal Article
%R 
%& 152
%P 10
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 46
%N 3
%@ 0039-2480
%8 2017-07-07
%7 2017-07-07
Cizelj, Leon, & Ferdo  Androjna.
"Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators." Strojniški vestnik - Journal of Mechanical Engineering [Online], 46.3 (2000): 152-161. Web.  20 Dec. 2024
TY  - JOUR
AU  - Cizelj, Leon 
AU  - Androjna, Ferdo 
PY  - 2000
TI  - Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - safety, aging; Inconel 600; steam generators; 
N2  - The paper reviews the domestic efforts devoted to the safe and reliable operation of the Krško nuclear power plant (NPP) at full power, close to the design limit of the steam generators (18% of plugged tubes) for a full decade. This includes an overview of the recent status and history of the degradation processes, discussion of repair criteria, defining the acceptable size of defects and selected results from safety analyses supporting the operation of degraded steam generator (SG) tubes. It is concluded that Krško NPP operated with degraded, but safe, steam generators.
UR  - https://www.sv-jme.eu/article/aging-of-tubes-in-the-krsko-nuclear-power-plants-steam-generators/
@article{{}{.},
	author = {Cizelj, L., Androjna, F.},
	title = {Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {46},
	number = {3},
	year = {2000},
	doi = {},
	url = {https://www.sv-jme.eu/article/aging-of-tubes-in-the-krsko-nuclear-power-plants-steam-generators/}
}
TY  - JOUR
AU  - Cizelj, Leon 
AU  - Androjna, Ferdo 
PY  - 2017/07/07
TI  - Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 46, No 3 (2000): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - safety, aging, Inconel 600, steam generators, 
N2  - The paper reviews the domestic efforts devoted to the safe and reliable operation of the Krško nuclear power plant (NPP) at full power, close to the design limit of the steam generators (18% of plugged tubes) for a full decade. This includes an overview of the recent status and history of the degradation processes, discussion of repair criteria, defining the acceptable size of defects and selected results from safety analyses supporting the operation of degraded steam generator (SG) tubes. It is concluded that Krško NPP operated with degraded, but safe, steam generators.
UR  - https://www.sv-jme.eu/article/aging-of-tubes-in-the-krsko-nuclear-power-plants-steam-generators/
Cizelj, Leon, AND Androjna, Ferdo.
"Aging of Tubes in the Krško Nuclear Power Plant’s Steam Generators" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 46 Number 3 (07 July 2017)

Authors

Affiliations

  • Institute Jože Stefan, Reactor Engineering Division, Ljubljana, Slovenia
  • Nuclear Power Plant Krško, Slovenia

Paper's information

Strojniški vestnik - Journal of Mechanical Engineering 46(2000)3, 152-161
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

The paper reviews the domestic efforts devoted to the safe and reliable operation of the Krško nuclear power plant (NPP) at full power, close to the design limit of the steam generators (18% of plugged tubes) for a full decade. This includes an overview of the recent status and history of the degradation processes, discussion of repair criteria, defining the acceptable size of defects and selected results from safety analyses supporting the operation of degraded steam generator (SG) tubes. It is concluded that Krško NPP operated with degraded, but safe, steam generators.

safety, aging; Inconel 600; steam generators;